Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Sci Total Environ ; 887: 163706, 2023 Aug 20.
Article in English | MEDLINE | ID: covidwho-2296989

ABSTRACT

Wastewater-based epidemiology is expected to be able to identify SARS-CoV-2 variants at an early stage via next-generation sequencing. In the present study, we developed a highly sensitive amplicon sequencing method targeting the spike gene of SARS-CoV-2, which allows for sequencing viral genomes from wastewater containing a low amount of virus. Primers were designed to amplify a relatively long region (599 bp) around the receptor-binding domain in the SARS-CoV-2 spike gene, which could distinguish initial major variants of concern. To validate the methodology, we retrospectively analyzed wastewater samples collected from a septic tank installed in a COVID-19 quarantine facility between October and December 2020. The relative abundance of D614G mutant in SARS-CoV-2 genomes in the facility wastewater increased from 47.5 % to 83.1 % during the study period. The N501Y mutant, which is the characteristic mutation of the Alpha-like strain, was detected from wastewater collected on December 24, 2020, which agreed with the fact that a patient infected with the Alpha-like strain was quarantined in the facility on this date. We then analyzed archived municipal wastewater samples collected between November 2020 and January 2021 that contained low SARS-CoV-2 concentrations ranging from 0.23 to 0.43 copies/qPCR reaction (corresponding to 3.30 to 4.15 log10 copies/L). The targeted amplicon sequencing revealed that the Alpha-like variant with D614G and N501Y mutations was present in municipal wastewater collected on December 4, 2020 and later, suggesting that the variant had already spread in the community before its first clinical confirmation in Japan on December 25, 2020. These results demonstrate that targeted amplicon sequencing of wastewater samples is a powerful surveillance tool applicable to low COVID-19 prevalence periods and may contribute to the early detection of emerging variants.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Wastewater , Japan , Prevalence , Retrospective Studies
2.
Sci Total Environ ; 843: 157101, 2022 Oct 15.
Article in English | MEDLINE | ID: covidwho-2211383

ABSTRACT

Wastewater-based epidemiology has attracted attention as a COVID-19 surveillance tool. Here, we developed a practical method for detecting SARS-CoV-2 RNA in wastewater (the EPISENS-S method), which employs direct RNA extraction from wastewater pellets formed via low-speed centrifugation. The subsequent multiplex one-step RT-preamplification reaction with forward and reverse primers for SARS-CoV-2 and a reverse primer only for pepper mild mottle virus (PMMoV) allowed for qPCR quantification of the targets with different abundances in wastewater from the RT-preamplification product. The detection sensitivity of the method was evaluated using wastewater samples seeded with heat-inactivated SARS-CoV-2 in concentrations of 2.11 × 103 to 2.11 × 106 copies/L. The results demonstrated that the sensitivity of the EPISENS-S method was two orders of magnitude higher than that of the conventional method (PEG precipitation, followed by regular RT-qPCR; PEG-QVR-qPCR). A total of 37 untreated wastewater samples collected from two wastewater treatment plants in Sapporo, Japan when 1.6 to 18 new daily reported cases per 100,000 people were reported in the city (March 4 to July 8, 2021), were examined using the EPISENS-S method to confirm its applicability to municipal wastewater. SARS-CoV-2 RNA was quantified in 92 % (34/37) of the samples via the EPISENS-S method, whereas none of the samples (0/37) was quantifiable via the PEG-QVR-qPCR method. The PMMoV concentrations measured by the EPISENS-S method ranged from 2.60 × 106 to 1.90 × 108 copies/L, and the SARS-CoV-2 RNA concentrations normalized by PMMoV ranged from 5.71 × 10-6 to 9.51 × 10-4 . The long-term trend of normalized SARS-CoV-2 RNA concentration in wastewater was consistent with that of confirmed COVID-19 cases in the city. These results demonstrate that the EPISENS-S method is highly sensitive and suitable for routine COVID-19 wastewater surveillance.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiology , Cost-Benefit Analysis , Humans , RNA, Viral , SARS-CoV-2/genetics , Wastewater , Wastewater-Based Epidemiological Monitoring
3.
BMJ Open ; 13(1): e066348, 2023 01 13.
Article in English | MEDLINE | ID: covidwho-2193795

ABSTRACT

OBJECTIVE: The relationship between the care of patients with COVID-19 and mental health among resident physicians in Japan is imperative for ensuring appropriate care of patients with COVID-19 and should be clarified. We herein assessed the relationship between the care of patients with COVID-19 and mental health among postgraduate year 1 (PGY-1) and PGY-2 resident physicians and factors associated with mental health. DESIGN: This nationwide cross-sectional study analysed data obtained using the clinical training environment self-reported questionnaire. SETTING: An observational study across Japan among resident physicians (PGY-1 and PGY-2) from 583 teaching hospitals. PARTICIPANTS: Examinees who took the general medicine in-training examination of academic year 2020. PRIMARY AND SECONDARY OUTCOME MEASURES: The Patient Health Questionnaire and Mini-Z 2.0 were used to assess mental health, and experience of caring for patients with COVID-19 was divided into three groups (none, 1-10 and ≥11). The prevalence of mental conditions in the three groups was compared using the 'modified' Poisson generalised estimating equations by adjusting for prefecture-level, hospital-level and resident-level variables. RESULTS: Of the 5976 participants analysed, 50.9% were PGY-1. The prevalence of burnout was 21.4%. Moreover, 47.0% of all resident physicians had no experience in the care of patients with COVID-19. The well-experienced group accounted for only 7.9% of the total participants. A positive association was found between the number of caring patients with COVID-19 and burnout (prevalence ratio 1.25; 95% CI 1.02 to 1.53). Moreover, the shortage of personal protective equipment was identified as a major contributor to burnout (prevalence ratio 1.60; 95% CI 1.36 to 1.88). CONCLUSIONS: Resident physicians who experienced more care of patients with COVID-19 had slightly greater burnout prevalence than those who did not. Approximately half of resident physicians did not participate in the care of patients with COVID-19, which posed a challenge from an educational perspective.


Subject(s)
Burnout, Professional , COVID-19 , Internship and Residency , Humans , Cross-Sectional Studies , Japan/epidemiology , COVID-19/epidemiology , COVID-19/therapy , Burnout, Professional/epidemiology , Burnout, Professional/psychology
4.
Sci Total Environ ; 849: 157869, 2022 Nov 25.
Article in English | MEDLINE | ID: covidwho-2049902

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is known to be present in sewage, and wastewater-based epidemiology has attracted much attention. However, the physical partitioning of SARS-CoV-2 in wastewater and the removal efficiency of treatment systems require further investigation. This study aimed to investigate the detectability and physical partitioning of SARS-CoV-2 in wastewater and assess its removal in a large-scale septic tank employing anaerobic, anoxic, and oxic processes in a sequential batch reactor, which was installed in a coronavirus disease 2019 (COVID-19) quarantine facility. The amount of SARS-CoV-2 RNA in wastewater was determined with polyethylene glycol (PEG) precipitation followed by quantitative polymerase chain reaction (qPCR), and the association of SARS-CoV-2 with wastewater solids was evaluated by the effect of filtration prior to PEG precipitation (pre-filtration). The amount of SARS-CoV-2 RNA detected from pre-filtered samples was substantially lower than that of samples without pre-filtration. These results suggest that most SARS-CoV-2 particles in wastewater are associated with the suspended solids excluded by pre-filtration. The removal efficiency of SARS-CoV-2 in the septic tank was evaluated based on the SARS-CoV-2 RNA concentrations in untreated and treated wastewater, which was determined by the detection method optimized in this study. Escherichia coli and pepper mild mottle virus (PMMoV) were also quantified to validate the wastewater treatment system's performance. The mean log10 reduction values of SARS-CoV-2, E. coli, and PMMoV were 2.47 (range, 2.25-2.68), 2.81 (range, 2.45-3.18), and 0.66 (range, 0.61-0.70), respectively, demonstrating that SARS-CoV-2 removal by the wastewater treatment system was comparable to or better than the removal of fecal indicators. These results suggest that SARS-CoV-2 can be readily removed by the septic tank. This is the first study to determine the removal efficiency of SARS-CoV-2 in a facility-level sequencing batch activated sludge system.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiology , Escherichia coli , Humans , Japan , Polyethylene Glycols , Quarantine , RNA, Viral , Sewage , Wastewater
SELECTION OF CITATIONS
SEARCH DETAIL